Illinois Business Center
Spaces
Professional Office Building - Multiple Spaces
Building description
Illinois Business Center, located adjacent to the State of Illinois Capitol Complex and just west of Springfield's Central Business District, has been serving office tenants since opening in 1989. Architecturally designed to include parking underneath the building at ground level with additional parking on surface lots. Monitored wet sprinkler system. Zoned heating and cooling for each floor. Two elevators plus three stairways (two directly from outside). Common handicapped accessible restrooms are located on central hallway of each floor.
Building highlights
Building Construction
Roof Steel joists-metal decking with single ply membrane on ½" recovery board with slope for adequate drainage and R-30 roll insulation
Foundation 12” reinforced poured concrete walls over reinforced concrete footings
Floor Structure 4" concrete with steel deck, steel joists and steel I-beam supports
Framing Steel beams and columns
Exterior Walls Jumbo brick and limestone; 6" steel stud with ½" exterior gyp board and R-20 fiberglass insulation
Windows Bronze aluminum frames with high energy solar glass
Interior Walls Drywall with thin coat plaster over 4" steel studs and sound deadening board
Ceilings Metal channel and acoustical tile
Lighting Recessed fluorescent fixtures
Floor Cover Common areas - ceramic / vinyl tile; Office areas - carpet
Doors-Trim Interior - steel jambs with 3' x 7' solid core oak; Exterior - top line heavy gage aluminum with commercial closer
Electrical Separately metered for all tenant spaces and HVAC systems; Metal conduit throughout; Caterpillar diesel generator supplies emergency service for elevators and part of 4th Floor
Bathrooms Each floor has two (2) ten fixture facilities
Stairways Three (3) with textured concrete over metal pans
Heating & AC Hot water (3 boilers) with forced air-air handlers; 210 tons of cooling
Elevators One 2,500 lb. capacity and One 3,500 lb. capacity (combination freight and passenger) each with five landings
Security All levels sprinklered and monitored fire alarm systems; fire extinguishers within each tenant space; emergency lighting with battery backups
Listing Contacts


Map
Property History
Similar Properties
Additional Information
Is there information that looks off?